Brita LP Water Dispenser 536897-002 Manual do Utilizador Página 24

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 74
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 23
22
PERFORMANCE DATA SHEET
Manufacturer Seller
BRITA GmbH BRITA Water Filter Systems
Heinrich-Hertz-Str. 4 Distributors Pty Ltd
65232 Taunusstein Unit 522 Narabang Way
Germany Belrose, NSW, 2085
+49-(0) 6128-746-0 Australia
http://www.brita.net/professional.html Tel +61 2 9486 4200
Fax +61 2 9486 4222
www.brita.com.au
PRODUCTS
Water Filter Systems
Purity C50 Quell ST Purity C150 Quell ST Purity C300 Quell ST
Filterhead 0–70% G3/8" Filterhead 0% G3/8" Filterhead 30% G3/8"
USE GUIDELINES
Minimum operating pressure: 2 bar Maximum operating pressure: 8.6 bar
Do not allow exposure to temperatures below 4 °C Maximum operating temperature: 30 °C
Nominal fl ow rates:
PURITY C50 Quell ST (60 l/h), PURITY C150 Quell ST (60 l/h), PURITY C300 Quell ST (60 l/h)
This system must be installed according to local plumbing codes on the cold water line.
Replacement Cartridges
PURITY C50 Quell ST Pack 3 (No. 1002502), PURITY C150 Quell ST Pack 1 (No. 1002506)
PURITY C300 Quell ST Pack 1 (No. 1002507)
This system requires regular replacement of the fi lter cartridge to maintain proper operation.
Varying scale, chlorine, sediment, or organic substance levels may affect replacement frequency.
Be sure to change the fi lter cartridge at least as indicated in the capacity table (refer to your
Instruction Guide) or annually which ever occurs fi rst, or whenever you detect a change in taste,
odour, or a decrease in fl ow.
Please ensure that a back ow prevention device, meeting the requirements of AS/NZS 3500.1,
is installed on the water supply inlet to the fi lter unit.
!
Caution: Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
SUBSTANCE REDUCTION
The above listed Water Filter Systems have been tested and certifi ed under NSF/ANSI 42 for reduc-
tion of chlorine, taste and odour. The performance of this product has been verifi ed and substanti-
ated as the test data summarised below indicates. These substances may not be in your water.
Test Data
Substance
Guidelines
Average
Infl uent
Concentration
Maximum
Effl uent
Concentration
Minimum
Percent
Removal
Average
Effl uent
Concentration
Average
Percent
Removal
Chlorine
NSF/ANSI 42 2.1 mg/l 0.255 mg/l 89.05% 0.1075 mg/l 95.25%
Testing Conditions:
Flow Rate: 0.25 GPM pH: 7.5+/0.5
Pressure: 60+/– 3 psgi Temperature: 20+/3°C